Backflow Prevention Resources

The Cross Connection Control Manual is a product of the Cross Connection Control Committee. The manual is under constant review and revisions are submitted and approved by the Committee at it's annual meeting, normally held in the spring of the year. The most recent version of the manual is the 2019 edition, updated in 2021.

The manual contains information on, legal and health aspects of cross connections control, the plumbing code and cross connections, the administrations of a cross control program, backflow mechanisms, typical hazards, and maintenance and testing of backflow prevention assemblies.

The manual is available to all those who concern themselves with the protection of potable water against contamination as a result of backflow through cross connection.

The National AWWA Cross Connection Control Manual is currently used by educational institutes accross Canada, with a French version available for Quebec.

Please contact your local AWWA Section office if you are outside of the WCS region
Only Alberta, Saskatchewan, Manitoba, Northern Territories & Nunavut orders will be processed by the WCS AWWA office.

CCC MANUAL ORDER FORM

Alberta

Gary Wagner - gdwags at gmail.com

Saskatchewan

Gerald Murray - gcwm5251 at gmail.com 

Manitoba

Matthew Fontaine - mrfontaine at rrc.ca

The WCS AWWA Cross Connection Control Committee meets once a year to manage the WCS AWWA CCC Program and the National CCC Manaul.

We collaborate with members of the Canadian CCC Coordinating Committee with respect to examination questions and procedures for use by accredited educational institutions.

Click here to view current Committee list

WCS AWWA does not endorse or recommend any of the products, services or companies associated with the links below. They are shared for information purposes only.

Alberta

 

Manitoba

Reding Instruments
1 3600 21 ST NE
Calgary, AB T2E 6V6
Phone: (403) 250-7430
www.redinginstruments.com

The Calibration Centre 
5304 Hubalta RD SE
Calgary, AB T2B 1T6
Phone: (403) 275-7090
flowtechservices@spswest.com

Zimco Gauge & Valve Ltd
5631 Burbank Rd SE
Calgary, AB T2H 1Z6
Phone: (403) 253-8320
www.zimco.ca

Western Gauge and Instruments Ltd.
4045 74 Ave S.E. 
Calgary AB T2C 2H9 
Phone 403 236-4888 
sales@wgiltd.com 
www.wgiltd.com

SPS West / Flow-Tech Services
5304 Hubalta Road SE
Calgary, AB T2B 1T6
Service: 403-291-0055
SPSWest.com / Envirobox.com 
FlowTechServices.ca

CPW Valve & Instrument Ltd.
100 7503 Girard Road
Edmonton, AB T6B 2H2
Phone: (780) 451-6888
cpwvalve@planet.eon.net 
www.cpwvalve.com

CPW Valve
Edmonton
http://www.cpwvalve.com/

Accutech Rentals Ltd
Edmonton
http://www.accutechrentals.com/

Western Gauge and Instruments Ltd
6624 50 Street
Edmonton AB T6B 2N7
Phone 780 463-3800
Fax 780 463-3990
edm@wgiltd.com
www.wgiltd.com

Jaron Wolff Process Controls Ltd.
9535 42 Avenue NW
Edmonton AB  T6E 5R2
Phone: 780-463-9527
Email: info@jaronwolff.com
Website: www.jaronwolff.com

VorTeqCal
(204) 334-1098

Trans Canada Calibration
(204) 878-4373 Ext: 232
1048 Arnold Road
Ile de Chenes MB R0A 0T0

Mantrol Instrumentation Services
Phone: 941-9969
160 Malmsbury Avenue
Winnipeg, MB R2N 2T4

in Winnipeg Drop off equipment at:

  • Crane Supply 
    1201 Sargent Ave.
  • BA Robinson Co. 
    1760 Ellice Ave.
  • Emco Corp.
    2030 Notre Dame Ave.
  • Mueller Flow Control
    777 Century St.

Methodologies for Setting a Cross-Connection Control Program is now posted on the InfraGuide Website at the following link:

http://www.infraguide.ca

AWWA offers the following information resources to provide a good understanding of various backflow devices, guidelines for acceptable practices, and the necessary criteria for a functioning, well-maintained and managed backflow and cross-connection control program.

Backflow Prevention and Cross-Connection Control (DVD)

Techniques and equipment for backflow prevention and cross-connection control, as described...Click to Learn More

Manual of Water Supply Practices

This manual is intended for use by all professionals charged with protecting the public water supply with proper backflow prevention and cross-connection control programs...Click to Learn More

BACKFLOW: The collection

set of related AWWA Standards and Manuals...Click to Learn More

Backflow Information Resources

  • All Things Backflow: The Water Knowledge Resource Community pageon Backflow is your one-stop shop for all AWWA information resources and publications available on the topic....Learn More
  • eLearning: Earn Continuing Education Units (CEU's) in this 2-hour webinar course on backflow prevention and cross-connection control...Learn More
  • Customer Education Materials:Keep your customers informed on the potential dangers related to backflow with these informative backflow prevention bill stuffers....Learn More
avp.gif ATMOSPHERIC VACUUM BREAKER
Applications: Irrigation systems, commercial dishwasher and laundry equipment, chemical tanks and laboratory sinks (backsiphonage only, nonpressurized connections.)
doublecheck.gif DOUBLE CHECK VALVE ASSEMBLIES
Applications: All non-health hazard (nontoxic) connections including: fire sprinkler and standpipe systems, irrigation systems, premise isolation.
reduce.gif REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER

Applications: Used to isolate severe hazards, where chemical or other health hazards exist including boiler systems or premises isolation.

dual.gif DUAL CHECK VALVE
Applications: Residential service connections and nontoxic point of use protection.
gap.gif AIR GAP
Applications: It's Applications range from extremely hazardous installations to a common household sink or wash basin. It provides an adequate air gap between the contaminant and the water supply.